Fiber Optic Modem
-------------
FOM-9
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
-
Synchronous or asynchronous
-
Single mode and multimode supported
-
Data rates up to 128 kbps sync and
115.2 kbps async
-
V.54 diagnostics, including local and
remote loopbacks
-
Built-in BERT in compliance with V.52
-
Full or half duplex
-
Controlled or continuous carrier
-
Internal, external or receive clock
-
Transmission range up to 16 km (10
miles) over single mode fiber
-
LED indicators
-
V.24, V.35, X.21 or RS-530 interface
options
-
Operates with an external power
supply (except FOM - 9/V.24/UP)
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Description |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |

-
The FOM - 9, Sync/Async Fiber Optic
Modem, is used for local data distribution, connecting full
or half duplex, sync or async terminals to computers over
single mode or multimode fiber optic cable. FOM - 9
operates at data rates of 32 to 128 kbps in sync mode or
9.6 to 115.2 kbps in async mode. FOM - 9 operates at
distances up to 16 km (10 miles) depending on the type of
fiber optic cable.
Each model has a 25-pin D-type
connector for the DTE interface. The V.35 interface is
supplied with a 45 cm (17.7") cable, with a 25-pin female
connector on one side and a 34-pin female connector on the
other side. The X.21 interface is supplied with a 45 cm
(17.7") cable with a 25-pin male connector on one side, and
a 15-pin X.21 female connector on the other side.
-
FOM - 9 includes a built-in V.52
standard BER tester for testing link integrity, activated by
a DIP switch. The BER tester checks the receive data and
turns on an ERROR LED, when an error is detected.
-
FOM - 9 includes six LEDs for
indicating signal status: RTS, TD, RD, CD, TST and ERR.
-
FOM - 9/V.24/UP's innovative
circuitry design allows operation without power supply, by
using ultra-low power from the standard RS-232/V.24 data and
control signals. For proper operation, both data and control
signals must be connected, i.e. TD, RD, RTS and DTR.
If the DTE cannot provide enough power for normal operation
of the unit, use FOM - 9/V.24.
-
FOM - 9/V.35, FOM - 9/X.21, FOM -
9/V.24 and FOM - 9/530 include a power jack for connection
of an external power supply. An additional external 9V DC
500 mA adapter should be ordered separately and used to