| PBX/KTS
Compatibility
The PBXgateway II supports leading PBX protocols
including:
•Alcatel: Omni PCX Enterprise and Office
•AvayaTM: DEFINITY®ECS (all G3 releases) and ECLIPS Media
Servers and Gateways (digital phones only)
•Ericsson: MD110•NEC: NEAX2000TM, NEAX2400TM, NEAX
Expressand Electra Elite
•Nortel: BCM, Meridian®and Norstar®•Panasonic: DBS 576 and
576HD
•Toshiba: Strata DK and CTX (digital phones only)
System Details
Dimensions:
•Size: 17" x 11" x 1" (432mm x 280mm x 44mm)
•Weight: 8.3 lbs (3.8 kg)Operating Environment:
•Temperature: 32° – 130° F (0° – 55° C)
•Relative humidity: 5 to 95% (non-condensing)Key
Features•Support for synchronous and asynchronous terminal
adapters•Encrypted username and password allocated by system
administrator to each port
•Network down recovery
•Call suspend mode on ISDN Lines with Asynch terminal
adapters
•Support for IP Precedence and DiffServ QoS mechanisms
General Set-Up Guidelines
•The PBX gateway II can be ordered with or without a 2-port
T1/PRI/FR network interface card.
•The PBX gateway II can be configured to run on IP transport
or traditional circuit-switched and frame relay networks.
•In a managed IP environment, running RVPoIP, the PBX
gateway II can be connected to the LAN via two 10/100 Base-T
ports simultaneously. One port can be configured for
administration access and the other can be configured for IP
voice traffic, allowing both traffic types to be transmitted
on separate LAN segments.
•In a point-to-point WAN environment, running serial RVP
between a MCK EXTender 6000 and a PBX gateway II, the
network access device is connected via one of the DB-25 WAN
ports.
•In a managed IP environment, the PBX gateway II supports
the EXTender 4000, 6000 and 7000.
•In a point-to-point WAN environment, the PBX gateway II
supports the EXTender 10001,30002, 6000 and 7000.
•One PBX gateway II can support both serial RVP and RVPoIP
remote clients simultaneously.
•Multiple EXTender 6000s and 7000s can be connected to one
PBX gateway II.
•The PBXgate way II is available with an integrated network
interface card that terminates T1, PRI andFR networks
directly, eliminating the need for external CSU/DSU devices.
•In IP applications, the network access device must be
configured to provide Quality of Service (QoS)in order to
guarantee voice quality. •IP or packet-based networks are
terminated through a router.
•Minimal setup programming required, accomplished via dial
up modem, Telnet, RS-232 console interface, inband RVP or
HTML interface.
Connectors included in backplane of unit:
•Internal power supply
•One PCM port for network expansion cards (optional)
providing connectors to a pair of RJ45 jacks for T1/PRI/FR
lines
•Two RJ-45 10/100 Base-T Ethernet for RVPoIP and Telnet/HTML
system management
•Two DB-25 WAN ports for serial RVP connection. Redundant
interfaces include V.35, RS-232 or RS-530
•One Amphenol connector for 50-pin RJ-21 cable for interface
with digital PBX ports Software Support
•TCP/IP protocol support for IP traffic and management
access
•RVPoIP uses UDP/IP protocol for voice transmission
•Serial RVP uses HDLC encapsulation for voice transmission
•Management and Utilities – Telnet, inband RVP, RS-232
console interface, SNMP and HTML
•Wind River’s VxWorks®operating system
•Software upgradeable via LAN FTP, RS-232 serial port to PC,
or inband connection between thePBX gateway II and the
EXTender 6000 and 7000
Voice Protocols
•Choice of voice compression standards:-G.729A (8
kbps)-G.726 (24 or 32 kbps ADPCM)-G.711 (64 kbps PCM)
•G.165 echo canceller software, with MCK proprietary
double-talk detection enhancement
•MCK Remote Voice Protocol (RVP)
•MCK Remote Voice Protocol over IP (RVPoIP)
•IP voice packets are tagged for network traffic
prioritization using IP Precedence or DiffServ
Hardware
•Form Factor: Low profile, 1U rack mountable unit Other
Components:
•Motorola MPC860T processor
•16 MB Flash Memory, 16 MB SDRAM
•DSP Analog Devices 2185 (52 MIPS)
Power Supply
•Internal, universal auto ranging
•Line voltage: 100 – 240 V
•Frequency: 47 – 63 Hz
•Maximum power consumption: 75 Watts
Regulatory Approvals
•FCC Part 15 Class A and FCC Part 68, CE Mark, Industry
Canada CS-03, NRTL/CSA, VCCI Class 1and CISPR 22 Class A
Warranty
•One-year limited warranty for parts and labor including
advance replacement when a unit isshipped back for repair.
|