Specifications

 

Signaling support : SS7,PRI,Q.SIG,R2,V5.2

Interface Connector:16x E1(T1),1x 10/100M network, 1x RS232 console
 
Link: 16x SS7 links,16x PRI

Switching Volume: 2048 x 2048
 
Clocking accuracy: stratum 3 Clock

Clocking Source: E1,inner.

Resource: 256 Voice channels,256 meeting channels,256 DTMF channels, FSK inspection and delivery

-Convert any signaling between SS7, ISDN PRI, Q.SIG,V5.2, R2
 
-Multi router, inter-office management, Intelligent router distribute and telephone traffic sharing
 
-Grouping switching management
 
-User identifier, can provide black and white name list or connect to the database

-Powerful calling function to provide customize calling mode
 
-Voice management function with voice record and voice play

-Meeting function

-Calling number and called number modification

-Real time telephone traffic monitor and handling

-Can expand the capacity through multi stack

-Provide CTILink API interface for user program control

 
Item
Specification
Input voltage
-48v DC or 200~240V AC
Power
30瓦
Dimension
(width�depth�height)
480mm�290mm�40mm (1U)
Weight
3 kg
Environment
Temperature
0℃~50℃
Rel Humidity
Less than 80%

  


 


 
 