Go to Pulse Home Page Pulse provides industry leading solutions, products and services for Data Communications, WAN and Computer Networking Call Pulse now for all your Datacomm, WAN and computer networking needs !
Click to go back one page
 

 

Adtran 1xE1 Wireless Transmission System

 

Adtran
 

Adtran  Tracer 2xE1  Wireless Transmission System
Specifications

 
 

 

Tracer transports an E1 digital signal in either HDB3 or AMI coding formats and provides either 75Ohm BNC or 120Ohm DB-15/RJ-48 interfaces.

A separate maintenance channel is embedded in the Tracer data stream, providing remote configuration and monitoring functions. The main-tenance channel is provided without impacting the E1 capacity.

By using the latest technology and incorporating ADTRAN's ISO 9001 manufacturing processes, ADTRAN has designed Tracer to provide the highest levels of reliability and durability.

Features

  • Digital Microwave Radio
  • E1 Interface
  • Direct Sequence Spread Spectrum
  • Frequency 2.4 to 2.4835 GHz
  • No License Required In Many Countries
  • Frequency Agile
  • Remote Loopback
  • Remote Control of Far-End
  • Rack or Mast-mounted RFC Option
  • 1U (4.4 cm), 48.3 cm (19" EIA) Rack Space using Mast-mounted RFC
  • Point-to-Point, Up to 48 km
 

Product Specifications

TRANSMITTER

  • Output Power: +20 dBm, Max
  • Frequency Band: 2.4 to 2.4835 GHz
  • Channel Bandwidth: 40 MHz
  • Intermediate Frequency: 140 MHz

RECEIVER

  • Receive Level Threshold: -91 dBm (10-6 BER)
  • Receive Level, Max: -30 dBm
  • Receive Level, Nominal: -60 dBm
  • Frequency Range: 2.4 to 2.4835 GHz
  • Channel Bandwidth: 40 MHz
  • Intermediate Frequency: 70 MHz

FREQUENCY PLAN

  • A - TX 2.422 GHz RX 2.462 GHz
  • B - TX 2.462 GHz RX 2.422 GHz

SPREAD SPECTRUM DATA PUMP

  • Modulation: QPSK
  • Spreading Method: Direct Sequence
  • Codes: 10
  • Code Length: 120
  • Processing Gain: >12 dB
  • Spreading Rate: 12 times

RADIO-FREQUENCY CONVERTER

  • Preselector Filter: Cavity tuned
  • Antenna Port: N-type, female
  • Impedance: 50 Ohm

E1 INTERFACE

  • Capacity: E1
  • Data Rate: 2.048 Mbps
  • Digital Interface: Meets G.703, G.704 & G.823
  • Line Code: AMI, HDB3
  • Connection Option 1: 75 Ohm - BNC
  • Connection Option 2: 120 Ohm - DB-15/RJ-48
  • Alarms: ALARM, LOS OOS, CV CRC
  • Loopbacks: Local & remote

USER INTERFACE

  • Front Panel: Status LEDs, configuration switches
  • Diagnostics: E1 loopback, remote test with BERT, self-test
  • Test Points: RSSI, system voltages, I & Q
  • Alarm Contacts: Major, minor (normally open or closed)

TERMINAL INTERFACE

  • Function: Menu-driven user interface, monitor & control of local & remote end, password protected, event history
  • Data Rate: 9600 Bps
  • Emulation: VT 100
  • Connection: DB-25 (RS-232)

BASEBAND PROCESSOR

  • Operating Temperature: -25° to 60° C
  • Width: 42.4 cm, (for 19" EIA rack mounting)
  • Height: 1U (4.4 cm)
  • Depth: 29.2 cm
  • Humidity: 95%, non-condensing
  • Weight: 2.7 kg

RACK-MOUNTED RFC

  • Operating Temperature: -40° to 65° C
  • Width: 42.4 cm, (for 19" EIA rack mounting)
  • Height: 1U (4.4 cm)
  • Depth: 29.2 cm
  • Humidity: 95%, non-condensing
  • Weight: 4.8 kg

MAST-MOUNTED RFC

  • Operating Temp: -40° to 65° C
  • Diameter: 22.5 cm
  • Height: 52.5 cm
  • Humidity: 100%
  • Weight: 8.1 kg

POWER

  • Input Voltage: 21 to 60 VDC
  • Power Consumption: 30 watts (amperage=30 watts/voltage)
  • DC Connector: 3 pin screw clamp
  • AC Adapter Connector: 3 pin DIN
*Systems are shipped with pre-configured frequency plans, but may be switched without additional equipment to accommodate either plan.
**Includes US style AC cord. Country specific power cord not included.
 
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

Ordering Information

  • E1 Tracer system* - 4280TRACERE1(options)
  • 100-240 VAC Adapter** - 1360DSK24VL1

Options

  • Mast-mounted, 75 Ohm BNC, preconfigured frequency plan A - L1-A
  • Mast-mounted, 75 Ohm BNC, preconfigured frequency plan B - L1-B
  • Mast-mounted, 120 Ohm DB-15/RJ-48, preconfigured frequency plan A - L3-A
  • Mast-mounted, 120 Ohm DB-15/RJ-48, preconfigured frequency plan B - L3-B
  • Rack-mounted, 75 Ohm BNC, preconfigured frequency plan A - L2-A
  • Rack-mounted, 75 Ohm BNC, preconfigured frequency plan B - L2-B
  • Rack-mounted, 120 Ohm DB-15/RJ-48, preconfigured frequency plan A - L4-A
  • Rack-mounted, 120 Ohm DB-15/RJ-48, preconfigured frequency plan B - L4-B
 

Specifications

PDF File

How to order products from Pulse

Application

Get Adobe Acrobat to read PDF files

 

  Can't find what you need ? Call or Email now !  

 

th11.jpg (990 bytes)

Home | Search | About | Offices | Manufacturers | Products | Services | Ordering
 Data101 | Training | Mailing | Hot ProductsDigital HQ | EmploymentEmail

 
Copyright© 2002 [Pulse, Inc.]. All rights reserved.
Pulse, Inc.
Tel: (toll free): 888-785-7393   Int'l: 1-561-279-7700  Fax: 561-279-7805 

Sales: sales